Regalmed | Medical Equipment in Dubai

Anaesthesia Workstation

SKU: 2710
  • Brand : Medion
  • Model : Asteros Royale Vent X

Short Description : 

  • 12.1 Inches Colour LCD Screen
  • Modes Of Ventilation VCV Volume ControlPCV Pressure Control PSV Pressure Support SIMV
  • ACMV Assist Control Ventilator With ePEEP (Electronic PEEP)
  • Spirometery (Loops And Waveforms) Minimum Tidal Volume Of 20mL

Standard Features : 

  • Minimum Tidal Volume Of 20ml
  • Suitable For Adults And Pediatric Range Of Patients
  • Comes With An Elegantly Designed 12.1 Inches Colour LCD Screen That Displays Several Parameters
  • Ventilator With Epeep (Electronic Peep)
  • Spirometry (Loops And Waveforms

Modes of Ventilation : 

  • VCV Volume Control
  • PCV Pressure Control
  • PSV Pressure Support
  • SIMV
  • ACMV Assist Control

Gas inlets : 

  • Cylinder Yokes : Gas Specific, Pin Indexed Yokes With Slinding Steel Clamping Bar For 02 And N2o As Per Model Below:  2×02, 2xn20
  • Pipeline Inlets:  02, N20 And Air Pipeline Inlets

Pressure Reducing Regulators :

  • Highly Efficient And Reliable Pressure Regulators (2 Stages In Prima) For O2 And N20.
  • N20 Regulators Are Activated Only If 02 Regulators Are Pressurized. N20 Regulators Cut Off On 02 Supply Failure

 Pressure Gauge :

  •   Pressure Gauge Cylinder: 02 And N20: 0 To 250 Kg/Cm2
  •  Pipeline Systems: 02/N20/Air, Diameter- Indexed
  •  02/N20 Piping Station Block With Pressure Gauge And 5m Hose (Optional)

Flowmeter : 

  •  5 Tube Long (230 Mm)
  • 3 Gas: 02, N2o, Air (Prima).
  •  Scale: 02 : 0.1-1 Lpm, 1-10 Lpm ,N20:0.1-1 Lpm, 1-10 Lpm,  Air: 0.1-10 Lpm

Vaporizer :

  •  Designed To Install Up To Maximum Two Selectatec Vaporizers.
  •  Breathing Attachment: Standard Bains Breathing Circuit

General Features :

  •  Operating Power: 100 To 240 Vac, 50/60hz, 6.5a Battery: 12v Dc, Battery Backup: 2 Hrs (Full Charge Time: 4 Hrs)
  • Screen: 12.1″ Color Lcd Display

Display Parameters : 

  • Real Time Display Of P-T, F-T, V-T Waveforms & P-V, F-V Loops, Etco2 (Optional),
  • A/C, Manual, Standby
  • Upto 4 Waveforms & 2 Loops Simultaneously.
  • Multigas Monitoring Parameters (Optional)
  • Digital Flow Meter (Optional)

CONTROL

  • Pressure, Volume And Time Controlled Ventilator
  • Modes: VCV, PCV, SIMV+PSV, Manual, Standby
  • Breath Rate: 1-100 Bpm
  • Tidal Volume: 20-1500 Ml
  • I: E Ratio:4:1-1:10
  • Peep: Integrated Electronic Peep: 4-30 Cmh2o
  • Flow Trigger: 1-15 L/Min
  • Insp. Time: 0.110 Sec (Increment: 0.1 Sec)
  • Pressure Limit: (Peep+5)-70 Cmh20
  • Pressure Control: 5-70 Cmh20
  • Pressure Support: 5-60 Cmh20
  • Inspiratory Pause: 5-50%

 MONITORING

  • Insp Tidal Volume: 0 To 1500ml
  • Exp Tidal Volume: 0 To 1500ml
  • Minute Volume: 0 To 60l
  • Spontaneous Minute Volume: 0 To 60l
  • Frequency: 0 To 100 Bpm
  • Spontaneous Frequency: 0 To 99 Bpm
  • I:E Ratio: 3:1 To 1:6
  • Peak Pressure: -12 To 100 Cmh20
  • Mean Pressure: 0 To 100 Cmh2o
  • Insp Plat Pressure: 0 To 100 Cmh2o
  • Insp 02:21% To 100%
  • Compliance: 0 To 200 ml/Cmh20
  • Resistance: 0 To 200cmh20/(L/S)
  •  Etco2

Reviews

There are no reviews yet.

Be the first to review “Anaesthesia Workstation”

Your email address will not be published. Required fields are marked *